10 inch PTFE pleated filter element with filter membrane for final air filter

                                                               PTFE Filter CartridgeIntroduction: The filtration media of PTFE micropore filter catridge is hydrophob

Featured Products

                                                               PTFE Filter Cartridge
Introduction:
 
The filtration media of PTFE micropore filter catridge is hydrophobicity PTFE membrane, it is constructed of two materials PTEE and PP to meet high standards of chemical and pharmaceutical industry. The benefit summary: strong hydrophobicity, high retention rate, super chemical tolerance and thermal stability, good intension, withstand shocks and back pressure. All products have passed 100% integrity accord with FDA and chinese Pharmacopoeia. 
 
Specifications:
 
Filter medium: hydrophobicity PTFE membrane
Support layer: PP
Filter cage: PP
Pore size: 0.1, 0.2, 0.45, 1 (um)
Length: 5", 10", 20", 30", 40"
Sealing material: Silastic, NBR, EPDM, Viton
Airtight method: thermal bonding technique
Effective filtration area: >=0.64square meter/10"
Diameter: 68mm
Working temperature: ≤65ºC
Max. operating temperature: 90ºC(P≤0.1Mpa)
Max. bear temperature: 140ºC, 0.27Mpa
Max. positive pressure: 0.42Mpa (23ºC)
PH value: 1--14
Sterilizing: temperature: 121ºC  30min
Others: special requirement of diameter and end caps can be customized
 
Typical Applications:
Chemical industry; Gas filtration etc.

 
Materials of Construction
MembranePTFE
Support and DrainagePP
Core, CagePP
End CapsDOE, SOE (code2, code3, code7, code8)
O-rings/GasketSilicone/EPDM/Viton/TEV
Sealing TechnologyThermal Bonding, No Adhesives
Dimensions
DiameterΦ68
Length5 inch, 10 inch, 20 inch, 30 inch, 40 inch
Filtration Area, ft 2
≥ 6.4 per 10-inch element
Pore Size, μm
0.01 (for gas),0.1, 0.2, 0.45, 1 (um)
Maximum Differential Pressure
Forward: 4.2 bar @ 23 C
Nitrogen Flow Rate & Pressure Drop , per 10-inch cartridge
≥ 60 m 3 /h at 0.1 bar with 0 bar outlet pressure
≥ 120 m 3 /h at 0.1 bar with 2 bar outlet pressure
Integrity Test - at 23 C
Bubble point≥ 1100 mbar with 60/40% IPA/water
HydroCorr (water intrusion test)≤ 0.75mL/min per 10-inch cartridge with water at 2620mbar

10'' PTFE Pleated Filter Cartridge with Filter Membrane for Final Air Filters
10'' PTFE Pleated Filter Cartridge with Filter Membrane for Final Air Filters

10'' PTFE Pleated Filter Cartridge with Filter Membrane for Final Air Filters
10'' PTFE Pleated Filter Cartridge with Filter Membrane for Final Air Filters
10'' PTFE Pleated Filter Cartridge with Filter Membrane for Final Air Filters
10'' PTFE Pleated Filter Cartridge with Filter Membrane for Final Air Filters

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours